Tubular Positive Plates |
| The batteries comprise of rugged Tubular Positive Plates One of the main rreasons for premature battery failure , more so in the case of flat pasted positive plates , is active material shedding due to cycling and vibration in traction applications . To overcome this problem and ensure longer life , the active material is held in place by a series of tubes have numerous minute pores which allow electrolyte to pass freely , minimising any loss of active materials. |
| Flexible Inter-cell Connectors |
| Flexible copper strap connectors do not snap or shear when subjected to small relative movements between adjacent cells experienced by motive power batteries in service. |
| Plastic Shrouds |
| Ceil HSP15 batteries are complete with insulating shrounds , made from high grade plastic , fitted on connectors and teminals In addition to preventing accidental short circuits , they protect the conductors from corrosion. |
| Electrolyte Level Sensor |
| A convenient way to ascertain when the battery needs toppind up , particularly when the battery is not easily accessible. |
| Choice ofVent Plugs |
| Normal Flip - Top vent plugs fitted with baskettype electrolyte level indicatorsor special type electrolyte level indicators or special type electrolyte level indicator vent plugs |
| Automatic Battery Filling system |
| Special auto-filling vent plugs , interconnected through tranparent tubes , are available as optional fitment . This allows precise and automatic filling of all cells when connected to a battery water source. |